User Access Level for UCV Series Phone

When the user clicks on the restricted icon or interface on the LCD screen, a pop-up window prompts to enter the password. After entering the correct password, it can be executed normally.

Feature Settings

First of all, there are 3 settings to control this feature.

Parameter Example

<P20952>$LcdItemLevelEnable$</P20952>

<LcdItemLevelEnable>$LcdItemLevelEnable$</LcdItemLevelEnable>

P Value Format

P20952

Description

Enable/Disable User Access Level for the phone LCD

0-Disable, 1-Enable

Example: <P20952>0</P20952>

        <LcdItemLevelEnable>1</LcdItemLevelEnable>

Permitted Values

Bool: 0 ~ 1

Default

0

Web UI

Blank

Phone UI

Blank

Parameter Example

<P24995>$UserAccessLevel$</P24995>

<UserLcdLevel>$UserAccessLevel$</UserLcdLevel>

P Value Format

P24995

Description

It configures the user access level of the phone.

A user with high level can access all the features in his user level and lower level. And 3-none means no limit.

0-user,1-var,2-admin,3-none            

Example: <P24995>3</P24995>

              <UserLcdLevel>3</UserLcdLevel>

Permitted Values

Int: 0-3

Default

3

Web UI

Blank

Phone UI

Blank

Parameter Example

<P20645>$Url$</P20645>

<Preference_ItemLevelUrl>$Url$</Preference_ItemLevelUrl>

P Value Format

P20645

Description

It configures the user access level xml file server url.

Example: <P20645>192.168.1.2/UserAccess.cfg</P20645>           <Preference_ItemLevelUrl>192.168.1.2/UserAccess.cfg</Preference_ItemLevelUrl>

Permitted Values

string;maxlength: 0-255

Default

Blank

Web UI

Blank

Phone UI

Blank

A minimal configuration file to provision these settings to the phone shown as below:

<?xml version="1.0" encoding="UTF-8" ?> <hl_provision version="1">     <config version="1">         <P20952 para="Preference_ItemLevelLcdEnable">1</P20952> <P24995 para="UserLcdLevel">0</P24995> <P20645 para="Preference_ItemLevelUrl">http://10.6.0.116:8099/UserAccess.cfg</P20645>    </config> </hl_provision>

UAL File

The format to specify the User Access Level of a fucntion in the UAL file is:

function = x

X represents the user level required to access the function.

When operating the function, if the phone does not meet the required level, a pop-up window will prompt that a password needs to be entered.

Now, there are 3 modules can apply the UAL:

  1. SystemUI: Restrict the button function of the drop-down menu.

  2. Launcher: Restrict desktop icon clicks and pop up a pop-up when accessing an application, format is Launcher-[package name]=X

  3. Settings: It is the access restriction for specific items under the Settings interface.

A UserAccess.cfg file configuration can be referred to:

[ SystemUI ] SystemUI-WiFi = 0 SystemUI-BT = 1 SystemUI-Forward = 1 SystemUI-VOIPDND = 2 SystemUI-Settings = 0 SystemUI-ScreenRecord =1 SystemUI-ScreenCast = 1 [ Launcher ] Launcher-com.htek.voip:DndEmptyActivity = 1 Launcher-com.android.vending = 1 [ Settings ] Settings-WiFi = 1 Settings-DND = 1 Settings-General = 1

 

After above settings, if the user access a feature without permission, the phone will prompt for password.

image-20240228-110120.png

Â